Compressor refrigeration high and low temperature box

Technical parameters:

(1) Use temperature range: (-40℃ ~ 320℃;)

(2) Temperature distribution accuracy fluctuation: ±1.5℃ (inside the center of the box ±100㎜ range)

(3) Temperature control display accuracy: ≤±0.1℃

(4) Refrigeration method: compressor refrigeration

(5) Studio size (width × depth × height) : 220mm×280mm×600mm

     Box dimensions (L × W × H) : EMC004B-1, 1820mm×650mm×930mm

(6) Heating method: stainless steel heating tube, SSR solid-state relay drive

(7) Air circulation inside the box: centrifugal fan forced circulation

(8) Temperature rise rate: ≈3℃/min (there will be deviations with different external ambient temperatures)

(9) Cooling speed: ≈2 ° C /min (there will be deviations with different external ambient temperatures)

(10) When heating up (set temperature is positive), the temperature is not allowed to exceed 2℃ of the set value

(11) When cooling (set temperature is negative), the temperature is not allowed to exceed -2 ° C of the set value

(12) Use environment: temperature: +5℃ ~ +35℃;Humidity: ≤85%;Atmospheric pressure: 86 ~ 106KPa

(13) Weight: EMC004B-1:310 kg

(14) Power: EMC004B-1:4.3kW

(15) Power supply: AC380(1±10%)V, three-phase four-wire + PGND